  • Glass Body Conductivity Cell Model TCC01

    Glass Body These Glass-body, Conductivity electrode/cell is designed to conductivity testing application for laboratory and field use. Suitable for tap water and quality control check in water purification plant. Each type of conductivity cell has two models with k=0.1 cm-1 and k=1.0 cm-1 cell constants. When selecting a conductivity cell, check the expected conductivity of the sample and then look at the cell constants of conductivity cells. Choose a conductivity cell that covers the expected sample conductivity. The higher the conductivity value of sample, the higher the cell constant required. A conductivity cell with k=1.0 cm-1 cell constant is the most commonly used because it measures low to high conductivity.

  • Glass Body Conductivity Cell Model TCC1

    Glass Body These Glass-body, Conductivity electrode/cell is designed to conductivity testing application for laboratory and field use. Suitable for tap water and quality control check in water purification plant. Each type of conductivity cell has two models with k=0.1 cm-1 and k=1.0 cm-1 cell constants. When selecting a conductivity cell, check the expected conductivity of the sample and then look at the cell constants of conductivity cells. Choose a conductivity cell that covers the expected sample conductivity. The higher the conductivity value of sample, the higher the cell constant required. A conductivity cell with k=1.0 cm-1 cell constant is the most commonly used because it measures low to high conductivity.

  • ORP Electrode Model MQ17

    Glass Body (Refillable KCl filled) TOSHCON-TOSHNIWAL produces high quality Laboratory sensors for redox potential measurement for varied applications for Swimming Pools/ Drinking water, Water disinfection and many others. Invariably the membrane Glass is called as the sensing tip of pH Sensor, but in Redox Sensors instead of membrane glass the sensing tip is Platinum or Gold. The shapes & costs vary but the measurement technique remains the same. The other part of the reference Sensor still remains similar in both pH & Redox and is produced with different Junctions and Electrolytes, depending on the application.

  • PH Electrode Industrial CAS

    Plastic Body, (Gel filled) The pH soil electrode measures the pH value, one of the most relevant information for soil properties and performance. The pH soil electrode is a glass body, refillable, single/double junction pH electrode. The conical shaped tip design allows for penetration into solids, semi solids and emulsions. This is ideal for the direct measurement of pH in soils and soil slurries.

  • Semi-MicroPH Electrode Model CASM

    CASM (Glass Body, KCl filled) Semi-Micro pH electrode is refillable with special thin glass tube sizes, suitable for very small volume liquid measurements. Semi-Micro glass body pH electrodes provide superior chemical resistance and can withstand high temperature extremes. Semi-micro electrodes are durable and provide reliable and accurate measurements of routine samples.

  • Micro PH Electrode Model CAM

    Suitable for accurate pH measurement in NMR cells Micro pH electrode is refillable with special thin glass tube sizes, suitable for small & very small volume liquid measurements.Microelectrodes are bio potential electrodes with an ultrafine tapered tip that can be inserted into individual biological cells. The volume of sample must be enough to cover the glass membrane and liquid junction of the pH electrode during measurement. Micro pH electrodes are constructed with thick glass membrane, that is highly resistant to impact and chemicals.

  • PH Electrode Model CAFD-LI

    Non Aqueous, Glass body Electrode Non-Aqueous pH Electrode, a versatile refillable, PH electrode ideal for measuring the pH of Non aqueous solutions like Oil Emulsions / Organic Solutions. Liquids can serve as solvents to dissolve solutes (i.e., solid, liquid or gaseous) to form solutions. The most common solvent is water. Solvents other than water are called non-aqueous solvents. Some examples of non-aqueous solvents are hexane, alcohol, oil, etc. It is a refillable, Single/double-junction, glass-body, combination pH electrode. The connector is BNC, compatible with any pH meter that has BNC input. The applications include testing of non-aqueous solvents, viscous solutions, and samples containing non-aqueous solvent (e.g., cosmetics, paints, etc.)

  • PH meter digital table model

    TOSHCON-TOSHNIWAL Digital series CL46+ Deluxe pH/Redox benchtop meter is eco- friendly, designed to measure pH and ORP with stable high input impedance amplifier to achieve high accuracy & quick response.

  • Bluetooth Impact Printer

    The new SF40A/BT is a portable printer that offers high performance, advanced functionality, and wireless Bluetooth connectivity to OHAUS balances and scales, making it suitable for environments that require cable-free printing, such as biological laboratory cabinets in the cleanroom.

  • TDS Conductivity Meter

    Supplied with Conductivity Cell K = 1.0, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Instruction & Operational Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

  • Analab Multiparameter Analyzer

    Supplied with Combination Glass pH Electrode (0-70ºC), Conductivity Cell K=1.0, Standard Buffer Tablets, Temperature Probe, Electrode Stand consists of Clamp, Base Plate & Rod, Dust Cover, DC Adaptor, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

  • ANALAB Flame Photometer

    Supplied with Two Filters (Na and K), Air Supply Unit, Atomizer Tube, Sample Beaker (06 Nos.), Gas Lighter, LPG Tube, Power Cord, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

  • Lx 300

    EP2 series Infinity Corrected Plan Achromatic objectives provide crisp and accurate images at all powers. The optical system allows for the introduction of digital accessories while maintaining the highest level of performance.

  • LMWB04

    Water bath adopts new design structure, which could avoid the leakage of steam. There are pointer type temperature controller and intellectual type temperature controller for selecting. The intellectual temperature controller has high lightness digital display and key operating button, which is easy to operate. It has high precision on controlling the temperature

  • LMION40

    LMION40 is a high-accuracy meter, used for measuring the ION concentration, ORP and pH values of liquids. The meter widely used in environmental studies, chemical labs, swimming pools, etc.

  • Conductivity Cell cc1,cc,2,cc3

    • Conductivity sensor measures the ability of a solution to conduct an electrical current
    • Presence of ions in a solution allows the solution to be conductive
    • Higher ion concentration results in higher conductivity
    • The same electrode can also be used to measure Resistivity, TDS, and Salinity of aqueous solutions (if supported by the meter)
    • Conductivity sensor selection should match the measuring range of the solution for accurate results
  • Model : µFlameCal10 | Make : ANALAB |

    Supplied with Two Filters (Na and K), Air Supply Unit, Atomizer Tube, Sample Beaker (06 Nos.), Gas Lighter, LPG Tube, Power Cord, Operational & Instruction Manual with SOP, Calibration Test Certificate (Without Traceability Document) and Warranty Card.

  • Duran Laboratory Bottles GL 45, Clear & Amber

    • Complies with the standards in ISO 4796-1:2016 – Laboratory glassware – Bottles – Part 1: Screw-neck bottles
    • Manufactured from DURAN® borosilicate glass 3.3; a neutral glass classified as Glass Type I according to USP <660>, EP (3.2.1), and JP <7.01>
    • Meets ASTM E438, Type I, Class A requirements
    • Standardized GL-thread and matching cap system for tight sealing and clean pouring
    • Retrace Code and certificate for manufacturing lot traceability
    • Fired-on, highly durable white print
    • Suitable for long-term storage
    • Easy-to-read scale with graduation marks to estimate the content